Inicio
Información del autor
Autor Mauricio Estrada Castrillón
Comentario :
Médico Radiólogo, Hospital Pablo Tobón Uribe
|
Documentos disponibles escritos por este autor (14)
Clasificado(s) por (Año de edición descendente) Refinar búsqueda
In vivo absolute quantification of carnosine in the vastus lateralis muscle with 1H MRS using a surface coil and water as internal reference / Vega, Gloria
[Publicación periódica]
Título : In vivo absolute quantification of carnosine in the vastus lateralis muscle with 1H MRS using a surface coil and water as internal reference Tipo de documento : documento electrónico Autores : Vega, Gloria, Autor ; Ricaurte, German, Autor ; Mauricio Estrada Castrillón, Autor ; Reyngoudt, Harmen, Autor ; Cardona, Oscar M., Autor ; Gallo Villegas, Jaime A., Autor ; Narváez Sánchez, Raúl, Autor ; Calderón, Juan C., Autor Fecha de publicación : 2023 ISBN/ISSN/DL : 98700011900 Idioma : Inglés (eng) Materias : Carnosine Palabras clave : Carnosine Proton magnetic resonance spectroscopy Skeletal muscle Vastus lateralis Gastrocnemius Clasificación: AC-2023-001 Resumen : Phantom’s experiments showed a maximum error of 7%, highlighting the validity of the measurements in the study setup. The carnosine concentrations (mmol/kg ww, mean?±?SD) measured in the GM were 6.8?±?2.2 with the VC (CcarVC) and 10.2?±?3.0 with the SC (CcarSC) (P?=?0.013; n?=?9). Therefore, a correction was applied to these measurements (CcarVC?=?0.6582*CcarSC), to make coils performance comparable (6.8?±?2.2 for VC and 6.7?±?2.0 for SC, P?=?0.97). After that, only the SC was used to quantify carnosine in the VLM, where a concentration of 5.4?±?1.5 (n?=?30) was found, with significant differences between men (6.2?±?1.3; n?=?15) and women (4.6?±?1.2; n?=?15). The error in quantitation was 5.3–5.5% with both coils. Nota de contenido : To standardize a method for 1H MRS intramuscular absolute quantification of carnosine in the thigh, using a surface coil and water as internal reference. Derechos de uso : Permiso de republicación otorgado al HPTU En línea : https://link.springer.com/article/10.1007/s00256-022-04149-8 Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=6164 [Publicación periódica] In vivo absolute quantification of carnosine in the vastus lateralis muscle with 1H MRS using a surface coil and water as internal reference [documento electrónico] / Vega, Gloria, Autor ; Ricaurte, German, Autor ; Mauricio Estrada Castrillón, Autor ; Reyngoudt, Harmen, Autor ; Cardona, Oscar M., Autor ; Gallo Villegas, Jaime A., Autor ; Narváez Sánchez, Raúl, Autor ; Calderón, Juan C., Autor . - 2023.
ISSN : 98700011900
Idioma : Inglés (eng)
Materias : Carnosine Palabras clave : Carnosine Proton magnetic resonance spectroscopy Skeletal muscle Vastus lateralis Gastrocnemius Clasificación: AC-2023-001 Resumen : Phantom’s experiments showed a maximum error of 7%, highlighting the validity of the measurements in the study setup. The carnosine concentrations (mmol/kg ww, mean?±?SD) measured in the GM were 6.8?±?2.2 with the VC (CcarVC) and 10.2?±?3.0 with the SC (CcarSC) (P?=?0.013; n?=?9). Therefore, a correction was applied to these measurements (CcarVC?=?0.6582*CcarSC), to make coils performance comparable (6.8?±?2.2 for VC and 6.7?±?2.0 for SC, P?=?0.97). After that, only the SC was used to quantify carnosine in the VLM, where a concentration of 5.4?±?1.5 (n?=?30) was found, with significant differences between men (6.2?±?1.3; n?=?15) and women (4.6?±?1.2; n?=?15). The error in quantitation was 5.3–5.5% with both coils. Nota de contenido : To standardize a method for 1H MRS intramuscular absolute quantification of carnosine in the thigh, using a surface coil and water as internal reference. Derechos de uso : Permiso de republicación otorgado al HPTU En línea : https://link.springer.com/article/10.1007/s00256-022-04149-8 Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=6164 Efficacy of high-intensity interval- or continuous aerobic-training on insulin resistance and muscle function in adults with metabolic syndrome: a clinical trial / Mauricio Estrada Castrillón
Título : Efficacy of high-intensity interval- or continuous aerobic-training on insulin resistance and muscle function in adults with metabolic syndrome: a clinical trial Tipo de documento : documento electrónico Autores : Mauricio Estrada Castrillón, Fecha de publicación : 2022 Títulos uniformes : European Journal of Applied Physiology Idioma : Inglés (eng) Resumen : Purpose: We carried out a randomized, clinical trial in adults of both sexes with metabolic syndrome (MS) to assess the efficacy of high-intensity, low-volume interval training (HIIT) compared to moderate-intensity continuous training (MICT) on insulin resistance (IR), muscle mass, muscle activation, and serum musclin. Methods: Fasting glycemia, insulinemia, and glycated haemoglobin were determined by conventional methods, IR by Homeostatic model assessment (HOMA), lean mass by Dual-Energy X-ray Absorptiometry, muscle activation through carnosine by Proton Magnetic Resonance Spectroscopy, and musclin by Enzyme-Linked ImmunoSorbent Assay before and after a supervised, three-times/week, 12-week treadmill programme. HIIT (n = 29) consisted of six intervals with one-minute, high-intensity phases at 90% of peak oxygen consumption (VO2peak). MICT (n = 31) trained at 60% of VO2peak for 30 min. Results: Patients had a mean age of 50.8 ± 6.0 years, body mass index of 30.6 ± 4.0 kg/m2, and VO2peak of 29.0 ± 6.3 mL.kg−1.min−1. Compared to MICT, HIIT was not superior at reducing Ln HOMA-IR (adjusted mean difference: 0.083 [95%CI − 0.092 to 0.257]), carnosine or musclin or at increasing thigh lean mass. HIIT increased carnosine by 0.66 mmol/kg.ww (95% CI 0.08–1.24) after intervention. Both interventions reduced IR, body fat percentage and increased total lean mass/height2 and VO2peak. Musclin showed a non-significant reduction with a small effect size after both interventions. Conclusion: Compared to MICT, HIIT is not superior at reducing IR, carnosine or musclin or at increasing skeletal muscle mass in adults with MS. Both training types improved IR, muscle mass and body composition. NCT03087721, March 22nd, 2017. Mención de responsabilidad : Jaime Gallo-Villegas, Leonardo A. Castro-Valencia, Laura Pérez, Daniel Restrepo, Oscar Guerrero, Sergio Cardona, Yeliana L. Sánchez, Manuela Yepes-Calderón, Luis H. Valbuena, Miguel Peña, Andrés F. Milán, Maria C. Trillos-Almanza, Sergio Granados, Juan C. Aristizabal, Mauricio Estrada-Castrillón, Raúl Narvaez-Sanchez, Jorge Osorio, Daniel C. Aguirre-Acevedo & Juan C. Calderón Referencia : Eur J Appl Physiol. 2022 Feb;122(2):331-344. DOI (Digital Object Identifier) : 10.1007/s00421-021-04835-w PMID : 34687360 En línea : https://link.springer.com/article/10.1007%2Fs00421-021-04835-w Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=5865 Efficacy of high-intensity interval- or continuous aerobic-training on insulin resistance and muscle function in adults with metabolic syndrome: a clinical trial [documento electrónico] / Mauricio Estrada Castrillón, . - 2022.
Obra : European Journal of Applied Physiology
Idioma : Inglés (eng)
Resumen : Purpose: We carried out a randomized, clinical trial in adults of both sexes with metabolic syndrome (MS) to assess the efficacy of high-intensity, low-volume interval training (HIIT) compared to moderate-intensity continuous training (MICT) on insulin resistance (IR), muscle mass, muscle activation, and serum musclin. Methods: Fasting glycemia, insulinemia, and glycated haemoglobin were determined by conventional methods, IR by Homeostatic model assessment (HOMA), lean mass by Dual-Energy X-ray Absorptiometry, muscle activation through carnosine by Proton Magnetic Resonance Spectroscopy, and musclin by Enzyme-Linked ImmunoSorbent Assay before and after a supervised, three-times/week, 12-week treadmill programme. HIIT (n = 29) consisted of six intervals with one-minute, high-intensity phases at 90% of peak oxygen consumption (VO2peak). MICT (n = 31) trained at 60% of VO2peak for 30 min. Results: Patients had a mean age of 50.8 ± 6.0 years, body mass index of 30.6 ± 4.0 kg/m2, and VO2peak of 29.0 ± 6.3 mL.kg−1.min−1. Compared to MICT, HIIT was not superior at reducing Ln HOMA-IR (adjusted mean difference: 0.083 [95%CI − 0.092 to 0.257]), carnosine or musclin or at increasing thigh lean mass. HIIT increased carnosine by 0.66 mmol/kg.ww (95% CI 0.08–1.24) after intervention. Both interventions reduced IR, body fat percentage and increased total lean mass/height2 and VO2peak. Musclin showed a non-significant reduction with a small effect size after both interventions. Conclusion: Compared to MICT, HIIT is not superior at reducing IR, carnosine or musclin or at increasing skeletal muscle mass in adults with MS. Both training types improved IR, muscle mass and body composition. NCT03087721, March 22nd, 2017. Mención de responsabilidad : Jaime Gallo-Villegas, Leonardo A. Castro-Valencia, Laura Pérez, Daniel Restrepo, Oscar Guerrero, Sergio Cardona, Yeliana L. Sánchez, Manuela Yepes-Calderón, Luis H. Valbuena, Miguel Peña, Andrés F. Milán, Maria C. Trillos-Almanza, Sergio Granados, Juan C. Aristizabal, Mauricio Estrada-Castrillón, Raúl Narvaez-Sanchez, Jorge Osorio, Daniel C. Aguirre-Acevedo & Juan C. Calderón Referencia : Eur J Appl Physiol. 2022 Feb;122(2):331-344. DOI (Digital Object Identifier) : 10.1007/s00421-021-04835-w PMID : 34687360 En línea : https://link.springer.com/article/10.1007%2Fs00421-021-04835-w Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=5865 Reserva
Reservar este documentoEjemplares(1)
Código de barras Número de Ubicación Tipo de medio Ubicación Sección Estado DD001803 AC-2021-115 Archivo digital Producción Científica Artículos científicos Disponible Musclin is related to insulin resistance and body composition, but not to body mass index or cardiorespiratory capacity in adults / Mauricio Estrada Castrillón
Título : Musclin is related to insulin resistance and body composition, but not to body mass index or cardiorespiratory capacity in adults Tipo de documento : documento electrónico Autores : Mauricio Estrada Castrillón, Fecha de publicación : 2021 Títulos uniformes : Endocrinology and Metabolism Idioma : Inglés (eng) Palabras clave : Hormones Musclin protein human (OSTN) Metabolic syndrome Insulin resistance Muscle skeletal Body composition Resumen : Background: We studied whether musclin function in humans is related to glycemic control, body composition, and cardiorespiratory capacity. Methods: A cross-sectional study was performed in sedentary adults with or without metabolic syndrome (MS). Serum musclin was measured by enzyme-linked immunosorbent assay. Insulin resistance (IR) was evaluated by the homeostatic model assessment (HOMA-IR). Body composition was determined by dual-energy X-ray absorptiometry and muscle composition by measuring carnosine in the thigh, a surrogate of fiber types, through proton magnetic resonance spectroscopy. Cardiorespiratory capacity was assessed through direct ergospirometry. Results: The control (n=29) and MS (n=61) groups were comparable in age (51.5±6.5 years old vs. 50.7±6.1 years old), sex (72.4% vs. 70.5% women), total lean mass (58.5%±7.4% vs. 57.3%±6.8%), and peak oxygen consumption (VO2peak) (31.0±5.8 mL O2./kg.min vs. 29.2±6.3 mL O2/kg.min). Individuals with MS had higher body mass index (BMI) (30.6±4.0 kg/m2 vs. 27.4±3.6 kg/m2), HOMA-IR (3.5 [95% confidence interval, CI, 2.9 to 4.6] vs. 1.7 [95% CI, 1.1 to 2.0]), and musclin (206.7 pg/mL [95% CI, 122.7 to 387.8] vs. 111.1 pg/mL [95% CI, 63.2 to 218.5]) values than controls (P Mención de responsabilidad : Yeliana L. Sánchez, Manuela Yepes-Calderón, Luis Valbuena, Andrés F. Milán, María C. Trillos-Almanza, Sergio Granados, Miguel Peña, Mauricio Estrada-Castrillón, Juan C. Aristizábal, Raúl Narvez-Sanchez, Jaime Gallo-Villegas, Juan C. Calderón Referencia : Endocrinol Metab (Seoul). 2021 Oct;36(5):1055-1068. DOI (Digital Object Identifier) : 10.3803/EnM.2021.1104 PMID : 34674511 Derechos de uso : CC BY-NC En línea : https://www.e-enm.org/journal/view.php?doi=10.3803/EnM.2021.1104 Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=5850 Musclin is related to insulin resistance and body composition, but not to body mass index or cardiorespiratory capacity in adults [documento electrónico] / Mauricio Estrada Castrillón, . - 2021.
Obra : Endocrinology and Metabolism
Idioma : Inglés (eng)
Palabras clave : Hormones Musclin protein human (OSTN) Metabolic syndrome Insulin resistance Muscle skeletal Body composition Resumen : Background: We studied whether musclin function in humans is related to glycemic control, body composition, and cardiorespiratory capacity. Methods: A cross-sectional study was performed in sedentary adults with or without metabolic syndrome (MS). Serum musclin was measured by enzyme-linked immunosorbent assay. Insulin resistance (IR) was evaluated by the homeostatic model assessment (HOMA-IR). Body composition was determined by dual-energy X-ray absorptiometry and muscle composition by measuring carnosine in the thigh, a surrogate of fiber types, through proton magnetic resonance spectroscopy. Cardiorespiratory capacity was assessed through direct ergospirometry. Results: The control (n=29) and MS (n=61) groups were comparable in age (51.5±6.5 years old vs. 50.7±6.1 years old), sex (72.4% vs. 70.5% women), total lean mass (58.5%±7.4% vs. 57.3%±6.8%), and peak oxygen consumption (VO2peak) (31.0±5.8 mL O2./kg.min vs. 29.2±6.3 mL O2/kg.min). Individuals with MS had higher body mass index (BMI) (30.6±4.0 kg/m2 vs. 27.4±3.6 kg/m2), HOMA-IR (3.5 [95% confidence interval, CI, 2.9 to 4.6] vs. 1.7 [95% CI, 1.1 to 2.0]), and musclin (206.7 pg/mL [95% CI, 122.7 to 387.8] vs. 111.1 pg/mL [95% CI, 63.2 to 218.5]) values than controls (P Mención de responsabilidad : Yeliana L. Sánchez, Manuela Yepes-Calderón, Luis Valbuena, Andrés F. Milán, María C. Trillos-Almanza, Sergio Granados, Miguel Peña, Mauricio Estrada-Castrillón, Juan C. Aristizábal, Raúl Narvez-Sanchez, Jaime Gallo-Villegas, Juan C. Calderón Referencia : Endocrinol Metab (Seoul). 2021 Oct;36(5):1055-1068. DOI (Digital Object Identifier) : 10.3803/EnM.2021.1104 PMID : 34674511 Derechos de uso : CC BY-NC En línea : https://www.e-enm.org/journal/view.php?doi=10.3803/EnM.2021.1104 Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=5850 Reserva
Reservar este documentoEjemplares(1)
Código de barras Número de Ubicación Tipo de medio Ubicación Sección Estado DD001788 AC-2021-100 Archivo digital Producción Científica Artículos científicos Disponible Documentos electrónicos
2021-100Adobe Acrobat PDF Sarcoma sinovial monofásico de tipo fibroblástico. Evaluación diagnóstica por RM y postratamiento mediante ADC: Presentación de un caso / Mauricio Estrada Castrillón ; Catalina Mejía Gómez
Título : Sarcoma sinovial monofásico de tipo fibroblástico. Evaluación diagnóstica por RM y postratamiento mediante ADC: Presentación de un caso Otros títulos : Monophasic fibroblastic synovial sarcoma. Diagnostic and post-treatment assessment by MRI and ADC: case report Tipo de documento : documento electrónico Autores : Mauricio Estrada Castrillón, ; Catalina Mejía Gómez, Fecha de publicación : 2019 Títulos uniformes : Revista Colombiana de Radiología Idioma : Español (spa) Palabras clave : Difusión Diagnóstico por imagen Sarcoma sinovial Imagen por resonancia magnética Resumen : El sarcoma sinovial representa entre el 2 al 10 % de todas las malignidades primarias de tejidos blandos, situándose en el cuarto lugar en frecuencia de los sarcomas de tejidos blandos. Es una neoplasia clasificada por la WHO (World Health Organization) bajo la categoría de tumores de diferenciación incierta, considerándose una malignidad entre intermedio y alto grado. El tratamiento estándar es la escisión quirúrgica, sin embargo, por su alta recurrencia y en los casos en que se asocia a metástasis o márgenes positivos después de la resección, se han planteado otros tratamientos como la quimio y radioterapia. La imaginología juega un papel importante en el diagnóstico, la estadificación y evaluación de la respuesta al tratamiento. Nuevas técnicas como el uso de difusión y mapas de ADC (Apparent Diffusion Coefficient, o coeficiente de difusión aparente) en resonancia magnética (RM) son útiles para evaluar las lesiones tumorales y la respuesta al tratamiento. En este artículo se presenta el caso de un paciente con un sarcoma sinovial monofásico, el diagnóstico por imágenes y evaluación del tratamiento mediante técnicas avanzadas de resonancia magnética como la difusión. Mención de responsabilidad : Mauricio Estrada Castrillón, Catalina Mejía Gómez, Patricia Eugenia Gil Serrano, Mauricio Franco Cano, Javier Carrascoso Arranz Referencia : Rev. colomb. radiol ; 28(4)2017. En línea : http://contenido.acronline.org/Publicaciones/RCR/RCR28-4/09_Sarcoma.pdf Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4297 Sarcoma sinovial monofásico de tipo fibroblástico. Evaluación diagnóstica por RM y postratamiento mediante ADC: Presentación de un caso = Monophasic fibroblastic synovial sarcoma. Diagnostic and post-treatment assessment by MRI and ADC: case report [documento electrónico] / Mauricio Estrada Castrillón, ; Catalina Mejía Gómez, . - 2019.
Obra : Revista Colombiana de Radiología
Idioma : Español (spa)
Palabras clave : Difusión Diagnóstico por imagen Sarcoma sinovial Imagen por resonancia magnética Resumen : El sarcoma sinovial representa entre el 2 al 10 % de todas las malignidades primarias de tejidos blandos, situándose en el cuarto lugar en frecuencia de los sarcomas de tejidos blandos. Es una neoplasia clasificada por la WHO (World Health Organization) bajo la categoría de tumores de diferenciación incierta, considerándose una malignidad entre intermedio y alto grado. El tratamiento estándar es la escisión quirúrgica, sin embargo, por su alta recurrencia y en los casos en que se asocia a metástasis o márgenes positivos después de la resección, se han planteado otros tratamientos como la quimio y radioterapia. La imaginología juega un papel importante en el diagnóstico, la estadificación y evaluación de la respuesta al tratamiento. Nuevas técnicas como el uso de difusión y mapas de ADC (Apparent Diffusion Coefficient, o coeficiente de difusión aparente) en resonancia magnética (RM) son útiles para evaluar las lesiones tumorales y la respuesta al tratamiento. En este artículo se presenta el caso de un paciente con un sarcoma sinovial monofásico, el diagnóstico por imágenes y evaluación del tratamiento mediante técnicas avanzadas de resonancia magnética como la difusión. Mención de responsabilidad : Mauricio Estrada Castrillón, Catalina Mejía Gómez, Patricia Eugenia Gil Serrano, Mauricio Franco Cano, Javier Carrascoso Arranz Referencia : Rev. colomb. radiol ; 28(4)2017. En línea : http://contenido.acronline.org/Publicaciones/RCR/RCR28-4/09_Sarcoma.pdf Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4297 Reserva
Reservar este documentoEjemplares(1)
Código de barras Número de Ubicación Tipo de medio Ubicación Sección Estado DD001277 AC-2019-067 Archivo digital Producción Científica Artículos científicos Disponible Utilidad de las secuencias funcionales por resonancia magnética en el estudio de los tumores óseos y de partes blandas. Revisión imaginológica / Gabriel Jaime Varela Aguirre ; Mauricio Estrada Castrillón ; Catalina Mejía Gómez
Título : Utilidad de las secuencias funcionales por resonancia magnética en el estudio de los tumores óseos y de partes blandas. Revisión imaginológica Otros títulos : Difusion and functional sequences: utility in the study of bone and soft tissue tumors. pictorial review Tipo de documento : documento electrónico Autores : Gabriel Jaime Varela Aguirre, ; Mauricio Estrada Castrillón, ; Catalina Mejía Gómez, Fecha de publicación : 2019 Títulos uniformes : Revista Colombiana de Radiología Idioma : Español (spa) Palabras clave : Imagen por resonancia magnética Difusión Neoplasias óseas Resumen : La resonancia magnética es la técnica de imagen de elección para diagnosticar, caracterizar, estadificar, realizar el seguimiento y valorar la respuesta al tratamiento de los tumores musculoesqueléticos. Para estos fines se utilizan las secuencias convencionales. Desde hace algunos años se han comenzado a implementar nuevas técnicas avanzadas, como la secuencia en fase y fase opuesta, difusión, perfusión y espectroscopia, que en conjunto se denominan técnicas funcionales, las cuales proporcionan información más específica del comportamiento, fisiología, metabolismo y biología molecular del tumor. Estas secuencias son no invasivas, aportan información adicional cualitativa, cuantitativa, metabólica y vascular por lo que deberían utilizarse de manera rutinaria en el momento de realizar el diagnóstico y, especialmente, en el seguimiento de los tumores óseos y de partes blandas. En este artículo se revisa la técnica de dichas secuencias, particularmente la secuencia de difusión, mediante casos ilustrativos de nuestros hospitales: Hospital Pablo Tobón Uribe y Hospital Universitario Quirón Salud de Madrid. También se revisarán las aplicaciones e importancia de un análisis combinado de estas nuevas herramientas, que aportarán información adicional para adecuada caracterización, enfoque diagnóstico y respuesta al tratamiento de las lesiones tumorales en el sistema musculoesquelético. Mención de responsabilidad : Catalina Mejía, Javier Carrascoso Arranz, Mauricio Estrada-Castrillón, Patricia Eugenia Gil Serrano, Gabriel Varela Referencia : Rev. Colomb. Radiol. 2019; 30(1): 5081-7 En línea : http://contenido.acronline.org/Publicaciones/RCR/RCR30-1/04_Secuencias.pdf Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4272 Utilidad de las secuencias funcionales por resonancia magnética en el estudio de los tumores óseos y de partes blandas. Revisión imaginológica = Difusion and functional sequences: utility in the study of bone and soft tissue tumors. pictorial review [documento electrónico] / Gabriel Jaime Varela Aguirre, ; Mauricio Estrada Castrillón, ; Catalina Mejía Gómez, . - 2019.
Obra : Revista Colombiana de Radiología
Idioma : Español (spa)
Palabras clave : Imagen por resonancia magnética Difusión Neoplasias óseas Resumen : La resonancia magnética es la técnica de imagen de elección para diagnosticar, caracterizar, estadificar, realizar el seguimiento y valorar la respuesta al tratamiento de los tumores musculoesqueléticos. Para estos fines se utilizan las secuencias convencionales. Desde hace algunos años se han comenzado a implementar nuevas técnicas avanzadas, como la secuencia en fase y fase opuesta, difusión, perfusión y espectroscopia, que en conjunto se denominan técnicas funcionales, las cuales proporcionan información más específica del comportamiento, fisiología, metabolismo y biología molecular del tumor. Estas secuencias son no invasivas, aportan información adicional cualitativa, cuantitativa, metabólica y vascular por lo que deberían utilizarse de manera rutinaria en el momento de realizar el diagnóstico y, especialmente, en el seguimiento de los tumores óseos y de partes blandas. En este artículo se revisa la técnica de dichas secuencias, particularmente la secuencia de difusión, mediante casos ilustrativos de nuestros hospitales: Hospital Pablo Tobón Uribe y Hospital Universitario Quirón Salud de Madrid. También se revisarán las aplicaciones e importancia de un análisis combinado de estas nuevas herramientas, que aportarán información adicional para adecuada caracterización, enfoque diagnóstico y respuesta al tratamiento de las lesiones tumorales en el sistema musculoesquelético. Mención de responsabilidad : Catalina Mejía, Javier Carrascoso Arranz, Mauricio Estrada-Castrillón, Patricia Eugenia Gil Serrano, Gabriel Varela Referencia : Rev. Colomb. Radiol. 2019; 30(1): 5081-7 En línea : http://contenido.acronline.org/Publicaciones/RCR/RCR30-1/04_Secuencias.pdf Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4272 Reserva
Reservar este documentoEjemplares(1)
Código de barras Número de Ubicación Tipo de medio Ubicación Sección Estado DD001251 AC-2019-041 Archivo digital Producción Científica Artículos científicos Disponible Efficacy of high-intensity, low-volume interval training compared to continuous aerobic training on insulin resistance, skeletal muscle structure and function in adults with metabolic syndrome: study protocol for a randomized controlled clinical trial (Intraining-MET) / Mauricio Estrada CastrillónPermalinkMR imaging of muscle trauma: anatomy, biomechanics, pathophysiology, and imaging appearance / Catalina Mejía Gómez ; Mauricio Estrada CastrillónPermalinkGiba carpiana, una patología frecuente / Mauricio Estrada Castrillón ; Jaime Alberto Londoño RestrepoPermalinkPolimialgia reumática: presentación de caso / Mauricio Estrada Castrillón ; Carlos Ignacio Gómez RoldánPermalinkLesiones quísticas de la rodilla. Revisión imaginológica / Mauricio Estrada Castrillón ; Jhon Byron Alzate ArboledaPermalinkSarcoma de Ewing de escápula: presentación de caso / Mauricio Estrada Castrillón ; Miguel Andrés Murcia HernándezPermalinkFractura femoral subtrocantérica atípica relacionada con el consumo de bifosfonatos: Presentación de caso / Mauricio Estrada CastrillónPermalinkIntra- and interobserver agreement on the Oestern and Tscherne classification of soft tissue injury in periarticular lower - limb closed fractures / Mauricio Estrada Castrillón ; Carlos Oliver Valderrama MolinaPermalinkPermalink