Efficacy of the Artificial Urinary Sphincter ZSI 375 for Treatment of Post-Radical Prostatectomy Incontinence in Patients with Intrinsic Sphincter Deficiency: A Preliminary Study / Federico Gaviria Gil
Título : Efficacy of the Artificial Urinary Sphincter ZSI 375 for Treatment of Post-Radical Prostatectomy Incontinence in Patients with Intrinsic Sphincter Deficiency: A Preliminary Study Tipo de documento : documento electrónico Autores : Federico Gaviria Gil, Fecha de publicación : 2017 Títulos uniformes : European Medical Journal Idioma : Inglés (eng) Resumen : Objectives: To evaluate the efficacy of the ZSI 375 artificial urinary sphincter (AUS) (Zephyr Artificial Sphincter, Geneva, Switzerland) for the treatment of patients with post-radical prostatectomy urinary incontinence. Methods: This was a retrospective, non-randomised, multicentre study open to patients with moderate-to-severe urinary incontinence due to intrinsic sphincter deficiency after radical prostatectomy. Efficacy and safety was evaluated on continence status, complications, and surgical revision. Results: Twenty-seven patients were recruited between September 2013 and April 2016 and followed up to April 2017. Mean age was 67.70 years old (range: 55–78). Twenty-six patients (96.30%) presented with incontinence post-radical prostatectomy and one patient (3.70%) after post-radical prostatectomy plus adjuvant radiotherapy. Follow-up ranged from 12 months–42 months (mean: 27.11). The success rate was 88.90% after 12 months follow-up, 94.12% after 24 months follow-up and 83.33% after 36 months follow-up. Three patients (11.11%) presented with a scrotal infection, two patients (7.41%) suffered a urethral erosion, and two patients (7.41%) had a mechanical failure. The revision rate was 22.22% (six patients). Conclusion: The follow-up time of this preliminary clinical study was long enough to demonstrate that the ZSI 375 AUS offers a good rate of continence to patients with urinary stress incontinence. Mención de responsabilidad : Alejandro Carvajal Obando, Federico Gavira Gil, Álvaro Gutiérrez Martinez, Luis Fernando Echeverry Molina, Juan Carlos Castaño Botero Derechos de uso : CC BY-NC En línea : https://www.emjreviews.com/urology/article/efficacy-of-the-artificial-urinary-sp [...] Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4686 Efficacy of the Artificial Urinary Sphincter ZSI 375 for Treatment of Post-Radical Prostatectomy Incontinence in Patients with Intrinsic Sphincter Deficiency: A Preliminary Study [documento electrónico] / Federico Gaviria Gil, . - 2017.
Obra : European Medical Journal
Idioma : Inglés (eng)
Resumen : Objectives: To evaluate the efficacy of the ZSI 375 artificial urinary sphincter (AUS) (Zephyr Artificial Sphincter, Geneva, Switzerland) for the treatment of patients with post-radical prostatectomy urinary incontinence. Methods: This was a retrospective, non-randomised, multicentre study open to patients with moderate-to-severe urinary incontinence due to intrinsic sphincter deficiency after radical prostatectomy. Efficacy and safety was evaluated on continence status, complications, and surgical revision. Results: Twenty-seven patients were recruited between September 2013 and April 2016 and followed up to April 2017. Mean age was 67.70 years old (range: 55–78). Twenty-six patients (96.30%) presented with incontinence post-radical prostatectomy and one patient (3.70%) after post-radical prostatectomy plus adjuvant radiotherapy. Follow-up ranged from 12 months–42 months (mean: 27.11). The success rate was 88.90% after 12 months follow-up, 94.12% after 24 months follow-up and 83.33% after 36 months follow-up. Three patients (11.11%) presented with a scrotal infection, two patients (7.41%) suffered a urethral erosion, and two patients (7.41%) had a mechanical failure. The revision rate was 22.22% (six patients). Conclusion: The follow-up time of this preliminary clinical study was long enough to demonstrate that the ZSI 375 AUS offers a good rate of continence to patients with urinary stress incontinence. Mención de responsabilidad : Alejandro Carvajal Obando, Federico Gavira Gil, Álvaro Gutiérrez Martinez, Luis Fernando Echeverry Molina, Juan Carlos Castaño Botero Derechos de uso : CC BY-NC En línea : https://www.emjreviews.com/urology/article/efficacy-of-the-artificial-urinary-sp [...] Enlace permanente : https://hospitalpablotobon.cloudbiteca.com/pmb/opac_css/index.php?lvl=notice_display&id=4686 Reserva
Reservar este documentoEjemplares(1)
Código de barras Número de Ubicación Tipo de medio Ubicación Sección Estado DD001166 AC-2017-121 Archivo digital Producción Científica Artículos científicos Disponible Documentos electrónicos